Tensile strength (BS2782 : 320A)
Unreinforced system 7N/mm2
Reinforced system 10 9N/mm2
Elongation (BS2782 : 320A)
Unreinforced system 300%
Reinforced system 10 30%
Tear strength (BS2782 : 32013)
Unreinforced system 7N/mm
Reinforced system 10 25/mm
Coating adhesion (ASTM D4541)
Unprimed concrete 2N/mm2
Primed concrete 3-5N/mm2
Thermal cycling/low temperature flexibility (BS3900 : E I : 1992)
Thermal cycled film (16 hours @ - 25*C/8 hours + 80*C.
7 cycles) tested at 0*C. Pass 5mm dia. mandrel
Freeze/thaw
Constant immersion, 16 hours @ - 20*C 8 hours @ -25*C. 5 cycles.
No significant changes in mechanical properties.
Impact Resistance
ASTM G 14-88 2.5 Joules
BS3900: E3 No cracking or detachment from substrate
Heat ageing (56 days) @ 70degrees
No significant changes in mechanical properties.
Water vapour transmission (ASTM E96/1653)
Specific permeability 25/m2/day
Resistance to fire (BS476 : Part)
Indicative test rating
Accelerated weathering (ASTM G53 - 2000 hours)
Minor surface chalking, no blisters, no loss of adhesion
Salt spray (ASTM B117 - 1000 hours)
Minor surface chalking, no blisters, no loss of adhesion
Water Absorption (ASTM D570)
7 days - 5% weight gain
21 days - 6.5% weight gain
The Guide to Sealing Apertures in Metal Roofs and Walls

Specification
Single pack, ultra high solids, polyurethane embedment and protection coat, partially or fully reinforced with Elastomat glass fibre matting to provide a membrane of excellent mechanical properties.
Suitable for a wide range of existing substrates, including bituminous surfaces, GRP, concrete, timbER, asphalt, approved insulation boards, metal profiled sheets and single ply systems.
Features
• Cold applied, using hand lay process
• Durable finish
• Reinforced with chopstand matting
• Can be applied during or after construction
• Minimal disruption
• Maintenance free